ACT D'MAND KONTROLS S3-100 Series Hot Water Recirculation Pumps
ACT Inc. pumps deliver hot water on demand, reduce water waste, and conserve energy. The D'MAND Kontrols® Recirculating Hot Water Pumps send cold water in the plumbing line back to the hot water heater, via the cold water or dedicated return line, while simultaneously bringing hot water to all fixtures on that plumbing line, in a matter of seconds. Unlike other hot water recirculation pumps, the D'MAND Kontrols® System does not allow hot water into the cold water line, and delivers hot water to the furthest fixtures on-demand, rather than on a timer based system.
The S3-100 includes an electronic circuit board, thermosensor mounted in stainless steel volute, 3/4" threaded stainless steel flanges, and internal check valve. 5 year warranty on pumps, 1 year on controls.
S3-100: Recommended for use with dedicated return lines in buildings up to 4,000 sq. ft. with tank water heaters, or pipe runs up to 200 lineal ft. with tankless water heaters.
S3-100-PFS: Recommended for use with standard plumbing (retrofit) in buildings up to 4,000 sq. ft. with tank water heaters, or pipe runs up to 100 lineal ft. with tankless water heaters.
Additional pump controls, including Bluetooth wireless controls, can be found on the ACT Accessories page.
ACT pump video (click for youtube.com video):
How the ACT system works:
At the push of a button, the ACT, Inc. Hot Water D'MAND Kontrol Systems® circulate the ambient temperature water in the hot water lines (water that is normally lost down the drain) back to the water heater. This occurs up to 80% faster than just letting the water run down the drain—the usual scenario. Depending on the plumbing layout, the route and time can vary. The D'MAND Kontrol Systems® move the water rapidly, so that the hot water arrives at the fixtures before the heat is lost through the pipe.
As the ambient temperature water in the cold water line travels towards the water heater, the D'MAND Kontrol Systems® fill the hot water line with hot water. When the hot water reaches the D'MAND Kontrol Systems®, a thermal sensor (thermister) senses a temperature rise and quickly shuts the pump off. The sophisticated electronic circuitry that does this is attached to the high-performance pump housing.
This results in getting hot water to the fixtures three to four times faster (on average), greater convenience in not having to wait, a savings in water and energy, and a reduction in sewage costs! As a by-product of these savings, a cumulative result is the improvement of air quality.
The D'MAND Kontrol Systems® can utilize the cold water line as a return line or it can use a dedicated return line. By using the existing cold water line, it is easy to retrofit existing homes or businesses. Special plumbing is not needed, and since the System will not allow for hot water to cross over to the cold water line, all the cold water fixtures still have cold water.
Catalog and specification files:
ACT D'MAND KONTROL System Information (PDF file)
S3-100 Pump Product Catalog (PDF file)
S3-100 Pump Installation Manual (PDF file)
PF-Kit (PF-KIT-BLUE) Accessory Specs (PDF file)
WRT-KIT-BT Bluetooth Wireless Kit Specs (PDF file)
WT-BT Bluetooth Additional Wireless Button Specs (PDF file)
HWB-CH-S Silver Button Specs (PDF file)
HWB-LED-S Flush Button Specs (PDF file)
Accessory images:
Do you have questions about the products on this page? Click on the ? image on the left or this link to ask us your questions! |
#1 | Q: Can this be installed outside? A: Not rated for outdoor installation unless you protect it from the elements. Typically installed under a sink indoors. Asked on 2022-06-05 by Ricky |
---|
Related Products
ACT D'MAND Pump Buttons and Wireless Accessories
Buttons, wireless controls and motion sensors for ACT D'MAND instant hot water pumps pumps. Standard and Bluetooth versions.
ACT D'MAND KONTROLS SS1-200 Series Hot Water Recirculation Pumps
For use in homes OVER 4,000 sq. ft. with tank/tankless water heaters or pipe runs OVER 200 lineal ft. with tankless heaters (100 feet for PFS kit unit).
ACT D'MAND KONTROLS ACT1 Hot Water Recirculation Pump
For use in homes UNDER 4,000 sq. ft. with tank/tankless water heaters and pipe runs UNDER 200 lineal ft. with tankless water heaters (100 feet for PF kit unit).
ACT D'MAND KONTROLS SS3-200 Hot Water Recirculation Pump
For use in homes OVER 4,000 sq. ft. with tank/tankless water heaters or pipe runs OVER 200 lineal ft. with tankless water heaters (100 feet for PF kit unit).
why buy from us?