ACT D'MAND KONTROLS SS3-200 Hot Water Recirculation Pump

ACT D'MAND pumps deliver hot water on demand, reduce water waste, and conserve energy. The D'MAND Kontrols® Recirculating Hot Water Pumps send cold water in the plumbing line back to the hot water heater, via the cold water or dedicated return line, while simultaneously bringing hot water to all fixtures on that plumbing line, in a matter of seconds. Unlike other hot water recirculation pumps, the D'MAND Kontrols® System does not allow hot water into the cold water line, and delivers hot water to the furthest fixtures on-demand, rather than on a timer based system. 5 year warranty on pumps, 1 year on controls.

The SS3-200 pump is for use with dedicated return lines in applications larger than 4,000 sq ft with tank water heaters or pipe runs over 200 lineal ft with tankless water heaters. It includes the pump and one hardwired activation button.

The SS3-200-PFS is recommended for use with standard (no deidcated return line) plumbing systems in buildings larger than 4,000 sq ft with tank water heaters or pipe runs over 100. The PFS kit adds flex lines, tees and a mounting bracket to the SS3-200 pump.

Additional pump controls can be found on the ACT Accessories page.

model description usually ships price QTY
SS3-200 DMAND Kontrols System pump package recommended for use with dedicated return lines in buildings larger than 4,000 sq ft with tank water heaters or pipe runs over 200 lineal ft. with tankless water heaters. Includes hardwired activation button. 1 Day. In-stock $1249.00
SS3-200-PFS DMAND Kontrols System pump package recommended for use with standard plumbing systems in buildings larger than 4,000 sq ft with tank water heaters or pipe runs over 100 lineal ft. between a tankless water heater and installation location of the D'MAND Kontrols®System. Includes: (1) hardwired activation button, (2) custom stainless steel tees, (2) 18 inch flex lines and (1) Mounting bracket. 1 Day. In-stock $1389.00
WRT-KIT-BT ACT DMAND Bluetooth wireless remote package. Contains 1 receiver and 1 transmitter button. System range of 50-60 feet. Other Bluetooth devices can be paired to receiver with the ACT app. 1 Day. In-stock $64.00
WT-BT ACT DMAND additional Bluetooth wireless transmitter/button. 50-60 foot range. Pair with REC-BT receiver. LED indicates that the unit is paired to receiver. 1 Day. In-stock $32.00
HWB-CH-S ACT DMAND accessory. Additional hardwired button. Round white center with CHROME ring. Momentary contact switch. 1 Day. In-stock $8.10
HWB-LED-S ACT DMAND accessory. Hardwired LED (green) silver activation button. Semi-flush design can be plate mounted (plate not included). Button illuminates when the system is activated and stays illuminated until it shuts down. Limit of 6 per system. 1 Day. In-stock $19.00
add to basket

real-time shipping quotes are available before checkout on your shopping cart page

  ACT pump video (click for youtube.com video):


  How the ACT system works:

standard plumbing KONTROL system

At the push of a button, the ACT, Inc. Hot Water D'MAND Kontrol Systems® circulate the ambient temperature water in the hot water lines (water that is normally lost down the drain) back to the water heater. This occurs up to 80% faster than just letting the water run down the drain—the usual scenario. Depending on the plumbing layout, the route and time can vary. The D'MAND Kontrol Systems® move the water rapidly, so that the hot water arrives at the fixtures before the heat is lost through the pipe.

As the ambient temperature water in the cold water line travels towards the water heater, the D'MAND Kontrol Systems® fill the hot water line with hot water. When the hot water reaches the D'MAND Kontrol Systems®, a thermal sensor (thermister) senses a temperature rise and quickly shuts the pump off. The sophisticated electronic circuitry that does this is attached to the high-performance pump housing.

ACT Metlund KONTROL SYSTEM

This results in getting hot water to the fixtures three to four times faster (on average), greater convenience in not having to wait, a savings in water and energy, and a reduction in sewage costs! As a by-product of these savings, a cumulative result is the improvement of air quality.

The D'MAND Kontrol Systems® can utilize the cold water line as a return line or it can use a dedicated return line. By using the existing cold water line, it is easy to retrofit existing homes or businesses. Special plumbing is not needed, and since the System will not allow for hot water to cross over to the cold water line, all the cold water fixtures still have cold water.

Do you have questions about the products on this page?

Click on the ? image on the left or this link to ask us your questions!
 

No questions yet. Be the first and send us your question!

Related Products

ACT D'MAND Pump Buttons and Wireless Accessories

Buttons, wireless controls and motion sensors for ACT D'MAND instant hot water pumps pumps. Standard and Bluetooth versions.

ACT D'MAND KONTROLS ACT1 Hot Water Recirculation Pump

For use in homes UNDER 4,000 sq. ft. with tank/tankless water heaters and pipe runs UNDER 200 lineal ft. with tankless water heaters (100 feet for PF kit unit).

ACT D'MAND KONTROLS S3-100 Series Hot Water Recirculation Pumps

For use in homes UNDER 4,000 sq. ft. with tank water heaters, or pipe runs UNDER 200 lineal ft. with tankless water heaters (100 feet for PF kit unit).

ACT D'MAND KONTROLS SS1-200 Series Hot Water Recirculation Pumps

For use in homes OVER 4,000 sq. ft. with tank/tankless water heaters or pipe runs OVER 200 lineal ft. with tankless heaters (100 feet for PFS kit unit).

 

why buy from us?

We're engineers passionate about home ventilation and serious about customer service – so you can count on us for carefully-selected equipment and expert advice to ensure your project is a success from specification to installation.

Your call is answered by qualified people who will gladly discuss your project in detail, advise you professionally and never sell you inappropriate products.